EN 3375-007 C WW
EN 3375-007 C WW
Data bus cable of multiplexed transmission.
77 Ohms, AWG 26 - Pair Double Shielded - High temperature
Description
Description
Normes
-
ProduitEN 3375-007
CORE
AWG 26, 19 x 0.10 mm
Silver plated high strength copper alloy
Fluoropolymer insulation
ASSEMBLY
2 cores twisted with 2 fillers
SHIELD
2 Silver plated copper braid
Strand diameter = 0.08 mm
Coverage ≥ 62%
JACKET
Fluoropolymer
Electrical and high frequency performances
Voltage rating | : 250V AC |
Characteristic impedance at 1 MHz | : 77 ± 7Ω |
Maximum capacitance | : 75 pF/m |
Maximum attenuation at 1 MHz | : 4.1 dB/100m |
Maximum transfert impedance | : 30 mΩ/m DC |
: 15 mΩ/m at 1 MHz | |
: 15 mΩ/m at 10 MHz | |
: 15 mΩ/m at 30 MHz |
Identification
Colour of cores | : Blue + White |
Colour of Jacket | : White |
JACKET CODE "NONE" | |
Colour of marking | : Green |
Marking text | : WW 26 FRF ** |
JACKET CODE "C01" | |
Colour of marking | : Red for the main line |
Marking text |
: WW R 26 FRF ** |
JACKET CODE "C02" | |
Colour of marking | : Blue for the branch line |
Marking text | : WW B 26 FRF ** |
With (**) = Year of manufacturing |
Caractéristiques
Caractéristiques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Température ambiante d'utilisation, plage
-65 ... 200 °C
Rayon de courbure minimum en utilisation statique
20 mm
Non propagateur de la flamme
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Résistance aux huiles
Very good resistance to aircraft fluids