SP 69899 - ASNE 0811 WY
SP 69899 - ASNE 0811 WY
Bus lines for multiplexed transmission. Use for bus system MIL STD 1553
77 Ohms, AWG 26 - Shielded Pair
Description
Description
Normes
-
ProduitASNE 0811 WY; ASNE 0811 WY
CORE
AWG 26, 19 x 0.10 mm
Silver plated copper alloy
(EN2083)
Insulation: extruded PTFE
ASSEMBLY
2 cores + 2 PTFE fillers
Nominal Diameter = 1.60 mm
SHIELD
Silver plated copper 10/100
JACKET
FEP
Electrical and high frequency performances
Voltage rating | : 250V |
Voltage withstanding | : 1000V between conductors |
: 1000V between conductors and shield | |
Jacket sperk test | : 5000V |
Insulation resistance | : ≥ 1500 MΩ.km |
Characteristic impedance | : 77 ± 7Ω at 1 MHz |
Nominal mutual capacitance | : 65 pF/m |
Nominal capacitance | : 110 pF/m between 1 core and shield |
: 180 pF/m between cores and shield | |
Nominal attenuation | : 3.5 dB/100m at 1 MHz |
Maximum transfer impedance | : 50 mΩ/m DC current |
: 50 mΩ/m at 1 MHz | |
: 50 mΩ/m at 10 MHz | |
: 100 mΩ/m at 30 MHz | |
Identification
Colour of cores | : White + Blue |
Colour of jacket | : White |
Marking text | : FILOTEX FRANCE ET 69899-** |
With | (**) = Year of manufacturing (ie. 14 = 2014) |
Red marking for the main line | : (Nexans reference = ETUDE 69899-01) |
Blue marking for the branch line | : (Nexans reference = ETUDE 69899-02) |
Caractéristiques
Caractéristiques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Température ambiante d'utilisation, plage
-65 ... 200 °C
Rayon de courbure minimum en utilisation statique
15 mm
Non propagateur de la flamme
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Résistance aux huiles
Bonne