STUDY 96770 - ASNE 0479 WJ - EN 3375-004B
STUDY 96770 - ASNE 0479 WJ - EN 3375-004B
Bus lines for multiplexed transmission.
77 Ohms, AWG 24 - Pair Double Shielded
Description
Description
Normes
-
ProduitEN 3375
CORE
AWG 24, 19 x 0.12 mm
Silver plated copper alloy (EN 2083)
Insulation: extruded PTFE
ASSEMBLY
2 cores twisted + 2 PTFE fillers
SHIELD
Tin plated copper 10/100
Tin plated copper 10/100
JACKET
FEP jacket
Electrical and high frequency performances
Voltage rating | : 250V |
Voltage withstanding | : 1000V between conductors |
: 1000V between conductors and shield | |
Jacket spark test | : 1000V |
Insulation resistance | : ≥ 1500 MΩ.km |
Characteristic impedance | : 77 ± 7 Ω at 1MHz |
Nominal mutual capacitance | : 65 pF/m |
Nominal capacitance | : 110 pF/m between 1 core and shield |
: 180 pF/m between cores and shield | |
Nominal attenuation | : 2.7 dB/100m at 1 MHz |
Maximum transfer impedance | : 15 mΩ/m DC current |
: 5 mΩ/m at 1 MHz | |
: 5 mΩ/m at 10 MHz | |
: 10 mΩ/m at 30 MHz | |
Identification
Marking text | : FILOTEX FRANCE ET 96770-** |
With | (**) = Year of manufacturing |
Red marking for the main line | (EN 3375-004 B01, Nexans reference : ETUDE 96770-01) |
Blue marking for the branch line | (EN 3375-004 B02, Nexans reference : ETUDE 96770-02) |
Caractéristiques
Caractéristiques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Température ambiante d'utilisation, plage
-65 ... 150 °C
Rayon de courbure minimum en utilisation statique
20 mm
Non propagateur de la flamme
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Résistance aux huiles
Bonne