WINDLINK® MV-RS (N) TSCGEHXOE 3+3

Products

(N)TSCGEHXOE 12/20 kV 3x95+3x50/3

Nexans ref.

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: Semi-conducting compound
  • Insulation: RHEYCLEAN-HEPR
  • Material of the external semi-conductor: Semi-conducting compound
  • Insulation sheath thickness: - mm
  • Phase Conductor Cross Section: 95 mm²
  • Nominal outer sheath thickness: - mm
  • Minimum outer diameter: 58.0 mm
  • Maximum outer diameter: 61.0 mm
  • Ground conductor cross-section: 16.7 mm²
  • Approximate weight: 5900 kg/km
  • Rated Voltage Uo/U (Um): 12/20 kV
  • Resistance of inner conductor (DC): - Ohm/km
  • Inductive reactance: - Ohm/km
  • Permissible short circuit current: - kA
  • Permissible current rating in open air: - A
  • Freely suspended length: 100 m

 

(N)TSCGEHXOE 18/30 kV 3x95+3x50/3

Nexans ref.

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: Semi-conducting compound
  • Insulation: RHEYCLEAN-HEPR
  • Material of the external semi-conductor: Semi-conducting compound
  • Insulation sheath thickness: - mm
  • Phase Conductor Cross Section: 95 mm²
  • Nominal outer sheath thickness: - mm
  • Minimum outer diameter: 69.0 mm
  • Maximum outer diameter: 72.0 mm
  • Ground conductor cross-section: 16.7 mm²
  • Approximate weight: 7300 kg/km
  • Rated Voltage Uo/U (Um): 18/30 kV
  • Resistance of inner conductor (DC): - Ohm/km
  • Inductive reactance: - Ohm/km
  • Permissible short circuit current: - kA
  • Permissible current rating in open air: - A
  • Freely suspended length: 100 m

 

(N)TSCGEHXOE 20/35 kV 3x50+3x16,7

Nexans ref. 71320041

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor:
  • Insulation: HEPR
  • Material of the external semi-conductor:
  • Insulation sheath thickness: 6.2 mm
  • Phase Conductor Cross Section: 50 mm²
  • Nominal outer sheath thickness: 4.6 mm
  • Minimum outer diameter: 63.0 mm
  • Maximum outer diameter: 66.0 mm
  • Ground conductor cross-section: 16.7 mm²
  • Approximate weight: 5750 kg/km
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV
  • Resistance of inner conductor (DC): 0.386 Ohm/km
  • Inductive reactance: 0.119 Ohm/km
  • Permissible short circuit current: 7.1 kA
  • Permissible current rating in open air: 192 A
  • Freely suspended length: 35 m

 

(N)TSCGEHXOE 20/35 kV 3x70+3x70/3

Nexans ref. 71320050

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor:
  • Insulation: HEPR
  • Material of the external semi-conductor:
  • Insulation sheath thickness: 5.7 mm
  • Phase Conductor Cross Section: 70 mm²
  • Nominal outer sheath thickness: 4.6 mm
  • Minimum outer diameter: 64.0 mm
  • Maximum outer diameter: 68.0 mm
  • Ground conductor cross-section: 25 mm²
  • Approximate weight: 6300 kg/km
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV
  • Resistance of inner conductor (DC): 0.272 Ohm/km
  • Inductive reactance: 0.11 Ohm/km
  • Permissible short circuit current: 10 kA
  • Permissible current rating in open air: 243 A
  • Freely suspended length: 46 m

 

(N)TSCGEHXOE 20/35 kV 3x95+3x95/3

Nexans ref. 71320029

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor:
  • Insulation: HEPR
  • Material of the external semi-conductor:
  • Insulation sheath thickness: 5.4 mm
  • Phase Conductor Cross Section: 95 mm²
  • Nominal outer sheath thickness: 5.1 mm
  • Minimum outer diameter: 68.0 mm
  • Maximum outer diameter: 72.0 mm
  • Ground conductor cross-section: 32 mm²
  • Approximate weight: 7500 kg/km
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV
  • Resistance of inner conductor (DC): 0.206 Ohm/km
  • Inductive reactance: 0.104 Ohm/km
  • Permissible short circuit current: 13.6 kA
  • Permissible current rating in open air: 296 A
  • Freely suspended length: 51 m

 

(N)TSCGEHXOE 20/35 kV 3x35+3x16,7

Nexans ref. 71320040

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: -
  • Insulation: HEPR
  • Material of the external semi-conductor: -
  • Insulation sheath thickness: 6.8 mm
  • Phase Conductor Cross Section: 35 mm²
  • Nominal outer sheath thickness: 4.6 mm
  • Minimum outer diameter: 62.0 mm
  • Maximum outer diameter: 67.0 mm
  • Ground conductor cross-section: 16.7 mm²
  • Approximate weight: 5030 kg/km
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV
  • Resistance of inner conductor (DC): 0.554 Ohm/km
  • Inductive reactance: 0.129 Ohm/km
  • Permissible short circuit current: 5 kA
  • Permissible current rating in open air: 158 A
  • Freely suspended length: 28 m

 

(N)TSCGEHXOE 20/35 kV 3x150+3x150/3

Nexans ref. 71320042

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: -
  • Insulation: HEPR
  • Material of the external semi-conductor: -
  • Insulation sheath thickness: 5.3 mm
  • Phase Conductor Cross Section: 150 mm²
  • Nominal outer sheath thickness: 5.6 mm
  • Minimum outer diameter: 75.0 mm
  • Maximum outer diameter: 79.0 mm
  • Ground conductor cross-section: 32 mm²
  • Approximate weight: 10100 kg/km
  • Rated Voltage Uo/U (Um): 20 / 35 (42) kV
  • Resistance of inner conductor (DC): 0.129 Ohm/km
  • Inductive reactance: 0.096 Ohm/km
  • Permissible short circuit current: 21.5 kA
  • Permissible current rating in open air: 385 A
  • Freely suspended length: 60 m

 

(N)TSCGEHXOE 8.7/15 kV 3x95+3x50/3

Nexans ref.

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: Semi-conducting compound
  • Insulation: RHEYCLEAN-HEPR
  • Material of the external semi-conductor: Semi-conducting compound
  • Insulation sheath thickness: - mm
  • Phase Conductor Cross Section: 95 mm²
  • Nominal outer sheath thickness: - mm
  • Minimum outer diameter: 56.0 mm
  • Maximum outer diameter: 59.0 mm
  • Ground conductor cross-section: 16.7 mm²
  • Approximate weight: 5600 kg/km
  • Rated Voltage Uo/U (Um): 8,7/15 kV
  • Resistance of inner conductor (DC): - Ohm/km
  • Inductive reactance: - Ohm/km
  • Permissible short circuit current: - kA
  • Permissible current rating in open air: - A
  • Freely suspended length: 100 m

 

(N)TSCGEHXOE 8.7/15 kV 3x150+3x70/3

Nexans ref.

  • Packaging: Cut to length (m)
  • Material of the inner semi-conductor: Semi-conducting compound
  • Insulation: RHEYCLEAN-HEPR
  • Material of the external semi-conductor: Semi-conducting compound
  • Insulation sheath thickness: - mm
  • Phase Conductor Cross Section: 150 mm²
  • Nominal outer sheath thickness: - mm
  • Minimum outer diameter: 64.0 mm
  • Maximum outer diameter: 67.0 mm
  • Ground conductor cross-section: 23.3 mm²
  • Approximate weight: 7900 kg/km
  • Rated Voltage Uo/U (Um): 8,7/15 kV
  • Resistance of inner conductor (DC): - Ohm/km
  • Inductive reactance: - Ohm/km
  • Permissible short circuit current: - kA
  • Permissible current rating in open air: - A
  • Freely suspended length: 100 m

 

Description

Description

Standards

  • International
    Nexans specification
  • National
    DIN VDE 0250 part 813

 

Application

WINDLINK® MV-RS (N)TSCGEHXOE was developed for special application condition in wind turbines.
The construction is torsion resistant by free hanging max. 100 m.
These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.

 

Design

Power-core
Conductor:
Copper, plain, flexible concentrically stranded circular, class 5 acc. to IEC 60228

Insulation:

  • Inner semi-conductive stress control layer, fixed with insulation
  • Elastomeric extruded special rubber compound RHEYCLEAN HV-EPR, quality better than 3GI3 acc. to DIN VDE 0207 part 20, based on EPDM, optimized wall thickness
  • Outer semi-conductive insulation shield layer, easy strip (thermostrip), compound basis EVA.

All three layers are extruded in one extrusion process and free of hollow space.

Protective-core
Conductor:
Copper plain, flexible concentrically stranded circular, class 5 acc. to IEC 60228
Conductor screen:
Extruded semi-conductive rubber

Inner Sheath
Extruded special rubber compound:
Quality better than GM1b, acc. to DIN VDE 0207 part 21, fulfils the requirements of EM1, nature colour, the filling of the interstices is integral part of the inner sheath and out of the same material, produced in the  same process with outer sheath.

Outer Sheath
Extruded special rubber compound:
Quality better than EM8 acc. DIN EN 50363-6, based on EVA,
water and oil resistant, flame retardant, abrasion and notch resistant,
colour: black, embossed marking e.g.:
WINDLINK MV-RS (N)TSCGEHXOE 3x25/25  18/30 kV INEXANSI year

 

Resistance to:

  • permanent movement
  • permanent vibrations
  • compressive stress
  • temporary influence of seawater
  • suitable for torsion of max. +/- 100°/m 
     

 

Complementary technical data for WINDLINK® MV loop rubber cables (over 6/10 kV)

Electrical data

Current-carrying capacity in ampere [A] at 30°C ambient temperature acc. to DIN VDE 0298-4 on ground:

Cross-section
[mm²]
over 6/10 kV
[A]

25

139

35

172
50 216
70 265
95 319
120 371
150 428
185 488
240 587
300 680
630 1385

Short circuit current-carrying capacity (1 sec) in kA. The constant K = 143 is calculated acc. to IEC 60949 (short circuit temperature 250°C and conductor temperature 90°C):

Cross-section
[mm²]

 for 1 sec
[kA]

25 3.6
35 5.0
50

7.2

70 10.0
95 13.6
120 17.2
150 21.5
185 26.5
240 34.3
300 42.9
630 90.1

COMPLEMENTARY TECHNICAL DATA FOR WINDLINK® MV LOOP RUBBER CABLES (OVER 6/10 KV)

Correction factor for ambient temperatures other than 30°C to be applied to the current-carrying capacities for cables in the air acc. to DIN VDE 0298-4 (permissible conductor temperature 90°C):

10°C

20°C

30°C

40°C

50°C

60°C

70°C

1.15

1.08

1.00

0.91

0.82

0.71

0.58

Max. conductor resistance for plain wires

Cross-section
[mm²]

at 20°C
[Ω/km]

at 90°C
[Ω/km]

25

0.780

0.998

35

0.554

0.706

50

0.386

0.494

70

0.272

0.348

95

0.206

0.264

120

0.161

0.206

150

0.129

0.165

185

0.106

0.135

240

0.0801

0.102

300

0.0641

0.0817

630

0.0287

0.0366

Permissible bending radii

fixed installation

6 x Ø

free movement

10 x Ø

Permissible tensile load

during installation

50 N/mm²

in operation

15 N/mm²

Cross-section in mm²: sum of all cores

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
-
Conductor material
Plain annealed copper
Conductor flexibility
Flexible class 5
Halogen free
IEC 60754
Inner sheath
-
Outer sheath
Halogen free flame retardant

Dimensional characteristics

Dimensional characteristics

Number of phases
3
Inner sheath thickness
- mm
Number of protection cores
3

Electrical characteristics

Electrical characteristics

Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km

Mechanical characteristics

Mechanical characteristics

Abrasion resistance
High
Cable flexibility
Flexible
Tear resistance
High
Maximum tensile strength
- N/mm2

Usage characteristics

Usage characteristics

Gases corrosivity
-
Flame retardant
IEC 60332-1-2
Oil resistance
EN 60811-2-1
Ozone resistance
Yes
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Dynamic bending factor
10 (xD)
Silicone free
Yes
Weather resistance
Yes
Smoke density
-

Resources

Resources

Documentation

xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close