- Markets
- Products
- Services
- Newsroom
- Tools & Resources
- About Nexans
- Search
- Contact us
- Compare
- Sign in
WINDLINK® MV-RS (N) TSCGEHXOE 3+3
WINDLINK® MV-RS (N) TSCGEHXOE 3+3
Torsion resistant medium voltage trailing cable for free hanging of max. 100 m
(N)TSCGEHXOE 12/20 kV 3x95+3x50/3
Nexans ref.
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: Semi-conducting compound
- Insulation: RHEYCLEAN-HEPR
- Material of the external semi-conductor: Semi-conducting compound
- Insulation sheath thickness: - mm
- Phase Conductor Cross Section: 95 mm²
- Nominal outer sheath thickness: - mm
- Minimum outer diameter: 58.0 mm
- Maximum outer diameter: 61.0 mm
- Ground conductor cross-section: 16.7 mm²
- Approximate weight: 5900 kg/km
- Rated Voltage Uo/U (Um): 12/20 kV
- Resistance of inner conductor (DC): - Ohm/km
- Inductive reactance: - Ohm/km
- Permissible short circuit current: - kA
- Permissible current rating in open air: - A
- Freely suspended length: 100 m
(N)TSCGEHXOE 18/30 kV 3x95+3x50/3
Nexans ref.
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: Semi-conducting compound
- Insulation: RHEYCLEAN-HEPR
- Material of the external semi-conductor: Semi-conducting compound
- Insulation sheath thickness: - mm
- Phase Conductor Cross Section: 95 mm²
- Nominal outer sheath thickness: - mm
- Minimum outer diameter: 69.0 mm
- Maximum outer diameter: 72.0 mm
- Ground conductor cross-section: 16.7 mm²
- Approximate weight: 7300 kg/km
- Rated Voltage Uo/U (Um): 18/30 kV
- Resistance of inner conductor (DC): - Ohm/km
- Inductive reactance: - Ohm/km
- Permissible short circuit current: - kA
- Permissible current rating in open air: - A
- Freely suspended length: 100 m
(N)TSCGEHXOE 20/35 kV 3x50+3x16,7
Nexans ref. 71320041
- Packaging: Cut to length (m)
- Material of the inner semi-conductor:
- Insulation: HEPR
- Material of the external semi-conductor:
- Insulation sheath thickness: 6.2 mm
- Phase Conductor Cross Section: 50 mm²
- Nominal outer sheath thickness: 4.6 mm
- Minimum outer diameter: 63.0 mm
- Maximum outer diameter: 66.0 mm
- Ground conductor cross-section: 16.7 mm²
- Approximate weight: 5750 kg/km
- Rated Voltage Uo/U (Um): 20 / 35 (42) kV
- Resistance of inner conductor (DC): 0.386 Ohm/km
- Inductive reactance: 0.119 Ohm/km
- Permissible short circuit current: 7.1 kA
- Permissible current rating in open air: 192 A
- Freely suspended length: 35 m
(N)TSCGEHXOE 20/35 kV 3x70+3x70/3
Nexans ref. 71320050
- Packaging: Cut to length (m)
- Material of the inner semi-conductor:
- Insulation: HEPR
- Material of the external semi-conductor:
- Insulation sheath thickness: 5.7 mm
- Phase Conductor Cross Section: 70 mm²
- Nominal outer sheath thickness: 4.6 mm
- Minimum outer diameter: 64.0 mm
- Maximum outer diameter: 68.0 mm
- Ground conductor cross-section: 25 mm²
- Approximate weight: 6300 kg/km
- Rated Voltage Uo/U (Um): 20 / 35 (42) kV
- Resistance of inner conductor (DC): 0.272 Ohm/km
- Inductive reactance: 0.11 Ohm/km
- Permissible short circuit current: 10 kA
- Permissible current rating in open air: 243 A
- Freely suspended length: 46 m
(N)TSCGEHXOE 20/35 kV 3x95+3x95/3
Nexans ref. 71320029
- Packaging: Cut to length (m)
- Material of the inner semi-conductor:
- Insulation: HEPR
- Material of the external semi-conductor:
- Insulation sheath thickness: 5.4 mm
- Phase Conductor Cross Section: 95 mm²
- Nominal outer sheath thickness: 5.1 mm
- Minimum outer diameter: 68.0 mm
- Maximum outer diameter: 72.0 mm
- Ground conductor cross-section: 32 mm²
- Approximate weight: 7500 kg/km
- Rated Voltage Uo/U (Um): 20 / 35 (42) kV
- Resistance of inner conductor (DC): 0.206 Ohm/km
- Inductive reactance: 0.104 Ohm/km
- Permissible short circuit current: 13.6 kA
- Permissible current rating in open air: 296 A
- Freely suspended length: 51 m
(N)TSCGEHXOE 20/35 kV 3x35+3x16,7
Nexans ref. 71320040
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: -
- Insulation: HEPR
- Material of the external semi-conductor: -
- Insulation sheath thickness: 6.8 mm
- Phase Conductor Cross Section: 35 mm²
- Nominal outer sheath thickness: 4.6 mm
- Minimum outer diameter: 62.0 mm
- Maximum outer diameter: 67.0 mm
- Ground conductor cross-section: 16.7 mm²
- Approximate weight: 5030 kg/km
- Rated Voltage Uo/U (Um): 20 / 35 (42) kV
- Resistance of inner conductor (DC): 0.554 Ohm/km
- Inductive reactance: 0.129 Ohm/km
- Permissible short circuit current: 5 kA
- Permissible current rating in open air: 158 A
- Freely suspended length: 28 m
(N)TSCGEHXOE 20/35 kV 3x150+3x150/3
Nexans ref. 71320042
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: -
- Insulation: HEPR
- Material of the external semi-conductor: -
- Insulation sheath thickness: 5.3 mm
- Phase Conductor Cross Section: 150 mm²
- Nominal outer sheath thickness: 5.6 mm
- Minimum outer diameter: 75.0 mm
- Maximum outer diameter: 79.0 mm
- Ground conductor cross-section: 32 mm²
- Approximate weight: 10100 kg/km
- Rated Voltage Uo/U (Um): 20 / 35 (42) kV
- Resistance of inner conductor (DC): 0.129 Ohm/km
- Inductive reactance: 0.096 Ohm/km
- Permissible short circuit current: 21.5 kA
- Permissible current rating in open air: 385 A
- Freely suspended length: 60 m
(N)TSCGEHXOE 8.7/15 kV 3x95+3x50/3
Nexans ref.
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: Semi-conducting compound
- Insulation: RHEYCLEAN-HEPR
- Material of the external semi-conductor: Semi-conducting compound
- Insulation sheath thickness: - mm
- Phase Conductor Cross Section: 95 mm²
- Nominal outer sheath thickness: - mm
- Minimum outer diameter: 56.0 mm
- Maximum outer diameter: 59.0 mm
- Ground conductor cross-section: 16.7 mm²
- Approximate weight: 5600 kg/km
- Rated Voltage Uo/U (Um): 8,7/15 kV
- Resistance of inner conductor (DC): - Ohm/km
- Inductive reactance: - Ohm/km
- Permissible short circuit current: - kA
- Permissible current rating in open air: - A
- Freely suspended length: 100 m
(N)TSCGEHXOE 8.7/15 kV 3x150+3x70/3
Nexans ref.
- Packaging: Cut to length (m)
- Material of the inner semi-conductor: Semi-conducting compound
- Insulation: RHEYCLEAN-HEPR
- Material of the external semi-conductor: Semi-conducting compound
- Insulation sheath thickness: - mm
- Phase Conductor Cross Section: 150 mm²
- Nominal outer sheath thickness: - mm
- Minimum outer diameter: 64.0 mm
- Maximum outer diameter: 67.0 mm
- Ground conductor cross-section: 23.3 mm²
- Approximate weight: 7900 kg/km
- Rated Voltage Uo/U (Um): 8,7/15 kV
- Resistance of inner conductor (DC): - Ohm/km
- Inductive reactance: - Ohm/km
- Permissible short circuit current: - kA
- Permissible current rating in open air: - A
- Freely suspended length: 100 m
Description
Description
Standards
-
InternationalNexans specification
-
NationalDIN VDE 0250 part 813
Application
WINDLINK® MV-RS (N)TSCGEHXOE was developed for special application condition in wind turbines.
The construction is torsion resistant by free hanging max. 100 m.
These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and usage outdoor.
Design
Power-core
Conductor:
Copper, plain, flexible concentrically stranded circular, class 5 acc. to IEC 60228
Insulation:
- Inner semi-conductive stress control layer, fixed with insulation
- Elastomeric extruded special rubber compound RHEYCLEAN HV-EPR, quality better than 3GI3 acc. to DIN VDE 0207 part 20, based on EPDM, optimized wall thickness
- Outer semi-conductive insulation shield layer, easy strip (thermostrip), compound basis EVA.
All three layers are extruded in one extrusion process and free of hollow space.
Protective-core
Conductor:
Copper plain, flexible concentrically stranded circular, class 5 acc. to IEC 60228
Conductor screen:
Extruded semi-conductive rubber
Inner Sheath
Extruded special rubber compound:
Quality better than GM1b, acc. to DIN VDE 0207 part 21, fulfils the requirements of EM1, nature colour, the filling of the interstices is integral part of the inner sheath and out of the same material, produced in the same process with outer sheath.
Outer Sheath
Extruded special rubber compound:
Quality better than EM8 acc. DIN EN 50363-6, based on EVA,
water and oil resistant, flame retardant, abrasion and notch resistant,
colour: black, embossed marking e.g.:
WINDLINK MV-RS (N)TSCGEHXOE 3x25/25 18/30 kV INEXANSI year
Resistance to:
- permanent movement
- permanent vibrations
- compressive stress
- temporary influence of seawater
- suitable for torsion of max. +/- 100°/m
Complementary technical data for WINDLINK® MV loop rubber cables (over 6/10 kV)
Electrical data
Current-carrying capacity in ampere [A] at 30°C ambient temperature acc. to DIN VDE 0298-4 on ground:
Cross-section [mm²] |
over 6/10 kV [A] |
25 |
139 |
35 |
172 |
50 | 216 |
70 | 265 |
95 | 319 |
120 | 371 |
150 | 428 |
185 | 488 |
240 | 587 |
300 | 680 |
630 | 1385 |
Short circuit current-carrying capacity (1 sec) in kA. The constant K = 143 is calculated acc. to IEC 60949 (short circuit temperature 250°C and conductor temperature 90°C):
Cross-section [mm²] |
for 1 sec |
25 | 3.6 |
35 | 5.0 |
50 |
7.2 |
70 | 10.0 |
95 | 13.6 |
120 | 17.2 |
150 | 21.5 |
185 | 26.5 |
240 | 34.3 |
300 | 42.9 |
630 | 90.1 |
COMPLEMENTARY TECHNICAL DATA FOR WINDLINK® MV LOOP RUBBER CABLES (OVER 6/10 KV)
Correction factor for ambient temperatures other than 30°C to be applied to the current-carrying capacities for cables in the air acc. to DIN VDE 0298-4 (permissible conductor temperature 90°C):
10°C |
20°C |
30°C |
40°C |
50°C |
60°C |
70°C |
1.15 |
1.08 |
1.00 |
0.91 |
0.82 |
0.71 |
0.58 |
Max. conductor resistance for plain wires
Cross-section |
at 20°C |
at 90°C |
25 |
0.780 |
0.998 |
35 |
0.554 |
0.706 |
50 |
0.386 |
0.494 |
70 |
0.272 |
0.348 |
95 |
0.206 |
0.264 |
120 |
0.161 |
0.206 |
150 |
0.129 |
0.165 |
185 |
0.106 |
0.135 |
240 |
0.0801 |
0.102 |
300 |
0.0641 |
0.0817 |
630 |
0.0287 |
0.0366 |
Permissible bending radii
fixed installation |
6 x Ø |
free movement |
10 x Ø |
Permissible tensile load
during installation |
50 N/mm² |
in operation |
15 N/mm² |
Cross-section in mm²: sum of all cores
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics