Nexans U-1000 AR2V 4G150

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502-1; NF C32-321

Application

Nexans U-1000 AR2V aluminium cables can be used in all low voltage power installations.

Our range also offers Nexans TWISTAL®, the twisted single-core version of Nexans U-1000 AR2V, specially designed to make three-phase links with neutral. Nexans TWISTAL® simplifies your life and offers many advantages :

  • Each core is spotted with a color band
  • The twisted core reduces the number of drums and cables pulling
  • This solution can allow to reduce the section of used cables (in parallel circuits)
  • Nexans TWISTAL® is more flexible and light than a multiconductor, allowing to increase comfort and saving of time

Installation

These cables can be fixed on cable trays, within conduits or fixed to walls.
They also can be buried directly with extra mechanical protection.

Design

  • Conductor: stranded circular aluminium - class 2 
  • Insulation: XLPE - cores identification by colours
  • Laying up (for multi conductors): with non hygroscopic filler
  • Outer sheath : Lead free black PVC 

Construction according to AD8 is possible on request

 

Marking

N (x ou G) S mm² U-1000 AR2V NF - USE N° Usine S.Y + Sans Pb

  • N = number of cores
  • S = section in mm²
  • G = with Green-Yellow
  • x = without Green-Yellow

 

 

Without mechanical protection, those cables can be fixed on the wall, cables trays or cable laders.

In buildings with explosion risks, they will be installed with particular protection. In this case, step down of 15% current carrying capacities.

 

Pulling on cable conductors

Tensile stress per mm2 of globale section shall in no case exceed 3 daN for LV aluminium cable.

The maximum pulling load must never exceed 2000 daN even rule above-mentionned sometimes leads to higher values for large section of cable.

Low carbon offer

Low carbon at a glance

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor flexibility
Stranded class 2
With smaller neutral conductor
No
Insulation
XLPE (chemical)
With Green/Yellow core
Yes
Outer sheath
PVC
Sheath colour
Black
Lead free
Yes
Conductor shape
Circular
Higher heating value
- MJ/km
Lay Up
Multicores

Dimensional characteristics

Dimensional characteristics

Number of cores
4
Conductor cross-section
150 mm²
Maximum outer diameter
52.5 mm
Approximate weight
3096 kg/km
Neutral conductor section (when smaller)
- mm²

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
0.206 Ohm/km
Permissible current rating in open air
304 A
Permissible current rating when buried
300 A
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Voltage drop, 3 conductors
0.44 V/A.km
Voltage drop, single phase
- V/A.km

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Rigid
Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Operating temperature, range
-25 ... 60 °C
Weather resistance
AN3
Chemical resistance
Accidental
Flame retardant
C2, NF C 32-070
Water proof
Intermittent
Minimum static operating bending radius
315 mm
Packaging
Cut to length

Resources

Resources

Declaration of Performance

  • Declaration of Performance n� : 1000279-FRJE
  • Certification Date : 11/29/16
  • AVCP (Assessment and Verification of Constancy of Performance) : System 3
  • Notified body : NB 1812
  • Declared performance : Eca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close