NEXANS NF C33-226 12/20(24)kV

Products

FR-N20XA8E-AR 1x 50/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10284930 - Country ref. 01273281

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 4.9 kA
  • Voltage drop, 3 conductors: 1.39 V/A.km
  • Minimum dynamic operating bending radius: 715.0 mm
  • Minimum static operating bending radius: 358 mm

 

FR-N20XA8E-AR 3x1x 50 Eca N/G BGN9 GL NEW

Nexans ref. 10284942 - Country ref. 01273289

  • Packaging: Cut to length (m)
  • Conductor cross-section: 50 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 4.9 kA
  • Voltage drop, 3 conductors: 1.39 V/A.km
  • Minimum dynamic operating bending radius: 771.0 mm
  • Minimum static operating bending radius: 385 mm

 

FR-N20XA8E-AR 1x 95/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10284931 - Country ref. 01273282

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 9.2 kA
  • Voltage drop, 3 conductors: 0.73 V/A.km
  • Minimum dynamic operating bending radius: 785.0 mm
  • Minimum static operating bending radius: 393 mm

 

FR-N20XA8E-AR 3x1x 95 Eca N/G BGN9 GL NEW

Nexans ref. 10284943 - Country ref. 01273290

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 9.2 kA
  • Voltage drop, 3 conductors: 0.73 V/A.km
  • Minimum dynamic operating bending radius: 840.0 mm
  • Minimum static operating bending radius: 420 mm

 

FR-N20XA8E-AR 1x150/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10284932 - Country ref. 01273283

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 14.5 kA
  • Voltage drop, 3 conductors: 0.49 V/A.km
  • Minimum dynamic operating bending radius: 788.0 mm
  • Minimum static operating bending radius: 394 mm

 

FR-N20XA8E-AR 3x1x150 Eca N/G BGN9 GL NEW

Nexans ref. 10285114 - Country ref. 01273291

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 14.5 kA
  • Voltage drop, 3 conductors: 0.49 V/A.km
  • Minimum dynamic operating bending radius: 849.0 mm
  • Minimum static operating bending radius: 424 mm

 

FR-N20XA8E-AR 1x240/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10284933 - Country ref. 01273284

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 23.1 kA
  • Voltage drop, 3 conductors: 0.33 V/A.km
  • Minimum dynamic operating bending radius: 900.0 mm
  • Minimum static operating bending radius: 450 mm

 

FR-N20XA8E-AR 3x1x240 Eca N/G BGN9 GL NEW

Nexans ref. 10285115 - Country ref. 01273292

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 23.1 kA
  • Voltage drop, 3 conductors: 0.33 V/A.km
  • Minimum dynamic operating bending radius: 969.0 mm
  • Minimum static operating bending radius: 484 mm

 

FR-N20XA8E-AR1x300/0.15 Eca N/G C33226 NEW

Nexans ref. 10286890

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 28.8 kA
  • Voltage drop, 3 conductors: 0.28 V/A.km
  • Minimum dynamic operating bending radius: 993.0 mm
  • Minimum static operating bending radius: 497 mm

 

FR-N20XA8E-AR3X1X300 Eca N/G C33226 NEW

Nexans ref. 10286894

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 28.8 kA
  • Voltage drop, 3 conductors: 0.28 V/A.km
  • Minimum dynamic operating bending radius: 1073.0 mm
  • Minimum static operating bending radius: 536 mm

 

FR-N20XA8E-AR1x400/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10285105 - Country ref. 01273286

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 38.9 kA
  • Voltage drop, 3 conductors: 0.23 V/A.km
  • Minimum dynamic operating bending radius: 1084.0 mm
  • Minimum static operating bending radius: 542 mm

 

FR-N20XA8E-AR 3x1x400 Eca N/G BGN9 GL NEW

Nexans ref. 10285117 - Country ref. 01273294

  • Packaging: Cut to length (m)
  • Conductor cross-section: 400 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 38.9 kA
  • Voltage drop, 3 conductors: 0.23 V/A.km
  • Minimum dynamic operating bending radius: 1149.0 mm
  • Minimum static operating bending radius: 575 mm

 

FR-N20XA8E-AR 1x630/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10285106 - Country ref. 01273287

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 60.2 kA
  • Voltage drop, 3 conductors: 0.17 V/A.km
  • Minimum dynamic operating bending radius: 1256.0 mm
  • Minimum static operating bending radius: 628 mm

 

FR-N20XA8E-AR 3x1x630 Eca N/G BGN9 GL NEW

Nexans ref. 10285118

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Number of cores: 3
  • Permissible short circuit current conductor 1s: 60.2 kA
  • Voltage drop, 3 conductors: 0.17 V/A.km
  • Minimum dynamic operating bending radius: 1353.0 mm
  • Minimum static operating bending radius: 677 mm

 

FR-N20XA8E-AR1x1200/0.15 Eca N/G BGN9 GL NEW

Nexans ref. 10285107

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1200 mm²
  • Number of cores: 1
  • Permissible short circuit current conductor 1s: 114.4 kA
  • Voltage drop, 3 conductors: 0.12 V/A.km
  • Minimum dynamic operating bending radius: 1604.0 mm
  • Minimum static operating bending radius: 802 mm

 

Description

Description

Standards

  • National
    NF C33-226

Usage

NF C33-226  cables are the new generation of cables for public power distribution network 12/20 kV.
They are AD8 (water pressure < 0,2 bar), AF2 and AN3 complying with NF C13-200 standard.
Sheath is anti-termite resistant.

 

Design

The cable is made of 1 or 3 bunched cores.

 

Electrical specifications

Calculations carried out in accordance with the IEC 60287 recommendation, given for information purposes, valid for a single joint trefoil connection and earthing of the screen at both ends.
The installation conditions must respect the rules of the art.
For the buried part, the cables are considered to be laid directly in the ground.
For the part in the open air, the cables are assumed to be laid on perforated cable trays, sheltered from the sun, at a distance from the walls equal to at least one cable diameter.

Soil resistivity: 0.85 K.m/W
Floor temperature: 20°C
Installation depth: 800 mm

Cable in the open air
Air temperature: 30°C

Short circuit characteristics according to IEC 60949.

Voltage drop is calculated for cos φ   = 0,9.

Options

NF C33-226 cables can be manufactured with the following options:

  • Rated voltage 18/30(36)kV
  • Version with messenger (+P50) in 3x1x50, 95 and 150mm² aluminium
  • Re-enforced burying resistance (NEXANS EDR MAX) is ensured with an extruded polyethylene protection.

Low carbon offer

Low carbon at a glance

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Material of the inner semi-conductor
Extruded
Insulation
XLPE
Material of the external semi-conductor
Extruded strippable smooth elastomer
Material used for longitudinal water tightness
Swellable tape
Screen
Longitudinal aluminium tape
Outer sheath
PE
Sheath colour
Black + 2 Grey Lines

Dimensional characteristics

Dimensional characteristics

Screen thickness
150 µm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
12 / 20 (24) kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
AG4

Usage characteristics

Usage characteristics

Ambient installation temperature, range
-10 ... 50 °C
Weather resistance
AN3 / AF2
Water proof
AD8

Resources

Resources

Selling & delivery Information

Marking

Example NEXANS - plant number - NF C33-226 int. designation- section - Al - 12/20 (24) kV - year - month -  installation guide type - G sheath thickness - SC semi-conductor thickness - EC screen thickness - RT installation temperature Eca

Metric marking

Marking "LOW CARBON"

The marking is metric over one core sheath, as well as a tracing mark.

Core identification: 1, 2, 3 helix-wise

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close