07RN8-F 4G1,5mm² + 2x1mm²

Description

Description

Standards

  • International
    EN 50525-2-21

Application

Cables are designed for power supply of submersible pumps and other devices used in water (including swimming pool water).

Design

 1. Conductor

Flexible bare or tinned copper Class 5.

  2. Insulation
   -Special crosslinked elastomer EI4

 3. Outer sheath

   - Special crosslinked elastomer EM2

   - Colour black

   - Other colours on request

Core colours

  • 2 cores (X) = Brown + Blue
  • 3 cores (G) = Green-Yellow + Brown + Blue
  • 3 cores (X) = Brown + Black + Grey
  • 4 cores (G) = Green-Yellow + Brown + Black + Grey
  • 4 cores (X) = Blue + Brown + Black + Grey
  • 5 cores (G) = Green-Yellow + Blue + Brown +  Black + Grey
  • 5 cores (X) =  Blue + Brown +  Black + Grey + Black

Marking

USE HAR H07RN8-F nb (x ou G) S mm² 269 NEXANS

Nota

For any request of specific cables, please join our contact team :

Copper conductors, specific  insulations and assemblies…

Outersheath : diameter, color, marking, unsheathing on automatic machines…

Packing on request…

Adapted delivery time…

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Sheath colour
Black
Conductor flexibility
Flexible class 5
Conductor material
Bare copper
Outer sheath
Cross-linked elastomer

Dimensional characteristics

Dimensional characteristics

Nominal outer diameter
- mm
Number of cores
6
Conductor cross-section
1.5 mm²
Maximum outer diameter
- mm
Approximate weight
228 kg/km
Minimum outer diameter
- mm
Average insulation thickness
- mm
Average sheath thickness
- mm

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
- Ohm/km
Maximum permissible nominal current
- A
Rated Voltage Uo/U (Um)
450/750 V
Voltage drop, single phase
- V/A.km

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Chemical resistance
Good
Flame retardant
IEC 60332-1
Water proof
AD8
Packaging
Drum
Weather resistance
Good
Operating temperature, range
-25 ... 50 °C
Short-circuit max. conductor temperature
200 °C

Resources

Resources

Documentation

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close