Nexans M-DRUM TELEREPORT SIMP 2P0,6 200m IV*

Description

Description

Standards

  • Product
    NF C33-400
  • Test
    NF C32-070/C2

Applications

These cables are used for automatic data transfer from EDF cut out through remote read. In accordance with EDF specification 48 37 300.

Design

  • Conductor: Solid bare copper, diameter 0.6 mm
  • Insutation: Polyvinyl chloryde (PVC)
  • Tape: Polyester
  • Collective screen
    • Tinned copper drain wire
    • Aluminium/polyester tape
  • Outer sheath: Polyvinyl chloryde (PVC) Colour : Ivory UV resistant

 

Core identification

1st pair: light blue - white
2nd pair: red - dark blue

 

Technical characteristics

Loop resistance at 20°C : 120 < R(Ohm.km) < 133,2
Insulation resistance under 400 V direct current value after 1 min of operation > 1000 MOhm.
Dielectrical strength between conductors for 1 min : 1500 V
Capacitance at 50 kHz : 80 < C (nF/km) < 130
Typical impedance at 50 kHz : 75 < Zc(Ohm) < 115
Ambiant temperature : -15°C to +45°C

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Conductor flexibility
Solid class 1
Insulation
PVC
Overall screen
Tinned copper drain wire + aluminium/polyester tape
Outer sheath
PVC
Conductor shape
Circular

Dimensional characteristics

Dimensional characteristics

Number of pairs
2
Conductor diameter
0.6 mm
Minimum outer diameter
5.1 mm
Maximum outer diameter
5.3 mm
Approximate weight
37 kg/km
Conductor cross section in mm²
-

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
100 / 170 V

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
-

Usage characteristics

Usage characteristics

Length
200 m
Packaging
Coil
Operating temperature, range
-15 ... 45 °C
Max. conductor temperature in service
70 °C
Flame retardant
C2, NF C 32-070
Bending factor when installed
10 (xD)

Resources

Resources

Selling & delivery Information

Marking

TELEREPORT NFC 33-400 NEXANS 279 Manufacturing n° YYYY 

Declaration of Performance

  • Declaration of Performance n� : 1000095-FRLV
  • Certification Date : 5/24/17
  • AVCP (Assessment and Verification of Constancy of Performance) : System 4
  • Declared performance : Fca

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*