- Markets
- Products
- Services
- Newsroom
- Tools & Resources
- About Nexans
- Search
- Contact us
- Compare
- Sign in
EN 50288-7 XLPE Insulation IOS Armoured Fire Retardant
EN 50288-7 XLPE Insulation IOS Armoured Fire Retardant
- Instrumentation cables 170/300 V
- Individual & Overall Screen (IOS)
- Oil resistant
EN 50288-7 XLPE IOS Armoured 2x2x0,5
Nexans ref. 10134811
- Number of pairs: 2
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE IOS Armoured 2x2x0,75
Nexans ref. 10134818
- Number of pairs: 2
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE IOS Armoured 2x2x1
Nexans ref. 10134825
- Number of pairs: 2
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE IOS Armoured 2x2x1,5
Nexans ref. 10134832
- Number of pairs: 2
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE IOS Armoured 2x2x2,5
Nexans ref. 10168655
- Number of pairs: 2
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE IOS Armoured 5x2x0,5
Nexans ref. 10168665
- Number of pairs: 5
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE IOS Armoured 5x2x0,75
Nexans ref. 10168748
- Number of pairs: 5
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE IOS Armoured 5x2x1
Nexans ref. 10168654
- Number of pairs: 5
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE IOS Armoured 5x2x1,5
Nexans ref. 10168756
- Number of pairs: 5
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE IOS Armoured 5x2x2,5
Nexans ref. 10168697
- Number of pairs: 5
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE IOS Armoured 10x2x0,5
Nexans ref. 10168644
- Number of pairs: 10
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE IOS Armoured 10x2x0,75
Nexans ref. 10168724
- Number of pairs: 10
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE IOS Armoured 10x2x1
Nexans ref. 10168681
- Number of pairs: 10
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE IOS Armoured 10x2x1,5
Nexans ref. 10168758
- Number of pairs: 10
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE IOS Armoured 10x2x2,5
Nexans ref. 10168631
- Number of pairs: 10
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE IOS Armoured 20x2x0,5
Nexans ref. 10134816
- Number of pairs: 20
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE IOS Armoured 20x2x0,75
Nexans ref. 10134823
- Number of pairs: 20
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE IOS Armoured 20x2x1
Nexans ref. 10134830
- Number of pairs: 20
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE IOS Armoured 20x2x1,5
Nexans ref. 10134837
- Number of pairs: 20
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE IOS Armoured 20x2x2,5
Nexans ref. 10168683
- Number of pairs: 20
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE IOS Armoured 30x2x0,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE IOS Armoured 30x2x0,75
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE IOS Armoured 30x2x1,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE IOS Armoured 30x2x2,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These Instrumentation and communication are used to transmit analogue or digital signals in measurement and process control. They are well adapted to underground use in industrial applications where chemical and mechanical protections are needed (refinery areas, chemical plant...). The individual screening of each pair limits the consequence of crosstalk.
Design
Conductor:
Stranded bare copper class 2
Insulation:
Cross-linked polyethylene (XLPE)
Individual screen:
Polyester tape
Tinned copper drain wire
Aluminium backed polyester tape
Polyester tape
Overall screen:
Polyester tape
Tinned copper drain wire
Aluminium backed polyester tape
Inner sheath:
Polyvinyl chloride (PVC)
Armour:
Galvanized steel wires (SWA)
Outer sheath:
Polyvinyl chloride (PVC)
Colour: black
Other colour on request
Core identification
Pair: white - black
White core printed with pair number
Marking
NEXANS 279 XLPE/IND.+OA.SCR/PVC/SWA/PVC 170/300V Nber of pairs & cross-section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking
Standards
EN 50288-7 (design guide-lines)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Tinned copper conductors available on request
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania