EN 50288-7 XLPE Insulation OS Armoured LC Fire Retardant
EN 50288-7 XLPE Insulation OS Armoured LC Fire Retardant
- Instrumentation cables 170/300 V
- With lead cover (LC)
- Overall Screen (OS)
- Aliphatic and aromatic hydrocarbons resistant
EN 50288-7 XLPE OS Armoured LC 1x2x0,5
Nexans ref. 10134899
- Number of pairs: 1
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 2x2x0,5
Nexans ref. 10134900
- Number of pairs: 2
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 5x2x0,5
Nexans ref. 10186672
- Number of pairs: 5
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 10x2x0,5
Nexans ref. 10186685
- Number of pairs: 10
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 20x2x0,5
Nexans ref. 10134905
- Number of pairs: 20
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 30x2x0,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE OS Armoured LC 1x2x0,75
Nexans ref. 10134907
- Number of pairs: 1
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 2x2x0,75
Nexans ref. 10134908
- Number of pairs: 2
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 5x2x0,75
Nexans ref. 10186691
- Number of pairs: 5
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 10x2x0,75
Nexans ref. 10186704
- Number of pairs: 10
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 20x2x0,75
Nexans ref. 10134913
- Number of pairs: 20
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 30x2x0,75
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE OS Armoured LC 1x2x1
Nexans ref. 10134915
- Number of pairs: 1
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 2x2x1
Nexans ref. 10134916
- Number of pairs: 2
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 5x2x1
Nexans ref. 10186710
- Number of pairs: 5
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 10x2x1
Nexans ref. 10186713
- Number of pairs: 10
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 20x2x1
Nexans ref. 10134921
- Number of pairs: 20
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 30x2x1
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE OS Armoured LC 1x2x1,5
Nexans ref. 10134923
- Number of pairs: 1
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 2x2x1,5
Nexans ref. 10134924
- Number of pairs: 2
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 5x2x1,5
Nexans ref. 10186718
- Number of pairs: 5
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 10x2x1,5
Nexans ref. 10186721
- Number of pairs: 10
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 20x2x1,5
Nexans ref. - Country ref. 10134923
- Number of pairs: 20
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 30x2x1,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE OS Armoured LC 1x2x2,5
Nexans ref. 10186726
- Number of pairs: 1
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE OS Armoured LC 2x2x2,5
Nexans ref. 10186727
- Number of pairs: 2
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE OS Armoured LC 5x2x2,5
Nexans ref. 10186730
- Number of pairs: 5
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE OS Armoured LC 10x2x2,5
Nexans ref. 10186734
- Number of pairs: 10
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE OS Armoured LC 20x2x2,5
Nexans ref. 10186740
- Number of pairs: 20
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE OS Armoured LC 30x2x2,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These instrumentation and communication cables are used to transmit analogue or digital signals in measurement and process control. They are well adapted to underground use in industrial applications, in moist areas, where hydrocarbon and mechanical protection are needed. The lead cover brings an enhanced resistance to aromatics hydrocarbons.
Design
Conductor:
Stranded bare copper class 2
Insulation:
Cross-linked polyethylene (XLPE)
Overall screen:
Polyester tape
Tinned copper drain wire,
Aluminium backed polyester tape
Inner sheath:
Polyvinyl chloride (PVC)
Colour: black
Lead sheath:
Bedding (intermediate sheath):
Polyvinyl chloride (PVC)
Colour: black
Armour:
Galvanized steel wires (SWA)
Outer sheath:
Polyvinyl chloride (PVC)
Colour: black
Other colour on request.
Core identification
Pair: white - black
Quad: white - black - red - blue (2 pair cables assembled as a quad)
White core printed with pair number
Marking
NEXANS 279 XLPE/OA.SCR/PVC//LC/PVC/SWA/PVC 170/300V Nber of pairs & cross-section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking
Standards
EN 50288-7 (Design guide lines)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Tinned copper conductors available on request