Thermocouple EN 50288-7 Hypron® XLPE Insulation OS Unarmoured Fire retardant

Products

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 1x2x0,5

Nexans ref.

  • Conductor cross-section: 0.5 mm²
  • Number of pairs: 1

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 5x2x0,5

Nexans ref.

  • Conductor cross-section: 0.5 mm²
  • Number of pairs: 5

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 10x2x0,5

Nexans ref.

  • Conductor cross-section: 0.5 mm²
  • Number of pairs: 10

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 30x2x0,5

Nexans ref.

  • Conductor cross-section: 0.5 mm²
  • Number of pairs: 30

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 1x2x1

Nexans ref.

  • Conductor cross-section: 1 mm²
  • Number of pairs: 1

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 5x2x1

Nexans ref.

  • Conductor cross-section: 1 mm²
  • Number of pairs: 5

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 10x2x1

Nexans ref.

  • Conductor cross-section: 1 mm²
  • Number of pairs: 10

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 20x2x1

Nexans ref.

  • Conductor cross-section: 1 mm²
  • Number of pairs: 20

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 30x2x1

Nexans ref.

  • Conductor cross-section: 1 mm²
  • Number of pairs: 30

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 1x2x1,34

Nexans ref.

  • Conductor cross-section: 1.34 mm²
  • Number of pairs: 1

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 5x2x1,34

Nexans ref.

  • Conductor cross-section: 1.34 mm²
  • Number of pairs: 5

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 10x2x1,34

Nexans ref.

  • Conductor cross-section: 1.34 mm²
  • Number of pairs: 10

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 20x2x1,34

Nexans ref.

  • Conductor cross-section: 1.34 mm²
  • Number of pairs: 20

 

EN 50288-7 Hypron® XLPE Insulation OS Unarmoured 30x2x1,34

Nexans ref.

  • Conductor cross-section: 1.34 mm²
  • Number of pairs: 30

 

Description

Description

Standards

  • International
    IEC 60332-3-22 Cat.A

Applications

These compensation and extension cables are used with thermocouples for temperature measurements in moist areas and where aliphatic and aromatic hydrocarbons may be present. Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution.

 

Design

Conductor:

Metals in accordance with the thermocouple, either solid cross section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.3 mm) or flexible cross section 1 mm² (14 x 0.30 mm)

Insulation:

Cross-linked polyethylene (XLPE)

Binder tape

Bedding

Inner sheath:

Polyvinyl chloride (PVC)

Colour: black.

Overall screen/sealing barrier

Tinned copper drain wire

Aluminium backed polyethylene tape

Bedding:

High density polyethylene (PE)

Colour: black

Special sheath (intermediate sheath):

Polyamide

Outer sheath:

Polyvinyl chloride (PVC)

Colour: depends on thermocouple type 

 

Core identification

See identification sheet

 

Marking

NEXANS 279 XLPE/PVC/AL/HDPE/NC/PVC 170/300V Nber of pairs & cross-section Type of thermocouple IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking

 

Standards

EN 50288-7 (Design guide-lines)

HD 446.3 S1

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Insulation
XLPE (Cross-linked Polyethylene)
Inner sheath
PVC
Overall screen
Tinned copper drain wire + aluminium/polyethylene tape
Material of bedding
High-density polyethylene (PE)
Intermediate sheath
Polyamide
Outer sheath
PVC
Lead free
Yes
Protection
no

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
170/300V

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Chemical resistance
Aliphatic and aromatic hydrocarbons resistant
Electro magnetic interference resistance
Yes
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
90 °C
Standard
EN

Resources

Resources

Documentation

Selling & delivery Information


Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.


Minimum bending radius:

15 x outer diameter
To be doubled during laying operations


Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close