Thermocouple EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured Fire retardant
Thermocouple EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured Fire retardant
- Thermocouple cables 170/300 V
- Individual & Overall Screen (IOS)
- Lead free
- Aliphatic and aromatic hydrocarbons resistant
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 5x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 5
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 10x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 10
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 20x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 20
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 30x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 30
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 5x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 5
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 10x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 10
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 20x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 20
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 30x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 30
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 5x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 5
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 10x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 10
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 20x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 20
EN 50288-7 Hypron® XLPE Insulation IOS Unarmoured 30x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 30
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These compensation and extension cables are used with thermocouples for temperature measurements in moist areas and where aliphatic and aromatic hydrocarbons may be present. The individual screening of each pair limits the consequence of crosstalk. Hypron® offers an alternative to conventional lead covered cable and is an environmental friendly solution.
Design
Conductor:
Metals in accordance with the thermocouple, either solid cross section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.3 mm) or flexible cross section 1 mm² (14 x 0.30 mm)
Insulation:
Cross-linked polyethylene (XLPE)
Individual screen:
Binder tape
Tinned copper drain wire
Aluminium/polyester tape
Binder tape
Binder tape
Bedding
Inner sheath:
Polyvinyl chloride (PVC)
Colour: black
Overall screen/sealing barrier:
Tinned copper drain wire
Aluminium backed polyethylene tape
Bedding:
High density polyethylene (PE)
Colour: black
Special sheath (intermediate sheath):
Polyamide
Outer sheath:
Polyvinyl chloride (PVC)
Colour: depends on thermocouple type
Core identification
See identification sheet
Marking
NEXANS 279 XLPE/IND.SCR/AL/HDPE/NC/PVC 170/300V Nber of pairs & cross-section Type of thermocouple IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking
Standards
EN 50288-7 (Design guide-lines)
HD 446.3 S1
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) on request.
Minimum bending radius:
15 x outer diameter