Thermocouple EN 50288-7 XLPE Insulation OS Armoured Fire retardant
Thermocouple EN 50288-7 XLPE Insulation OS Armoured Fire retardant
- Thermocouple cables 170/300 V
- Overall Screen (OS)
- Hydrocarbons resistant
EN 50288-7 XLPE Insulation OS Armoured 1x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 1
EN 50288-7 XLPE Insulation OS Armoured 5x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 5
EN 50288-7 XLPE Insulation OS Armoured 10x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 10
EN 50288-7 XLPE Insulation OS Armoured 20x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 20
EN 50288-7 XLPE Insulation OS Armoured 30x2x0,5
Nexans ref.
- Conductor cross-section: 0.5 mm²
- Number of pairs: 30
EN 50288-7 XLPE Insulation OS Armoured 1x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 1
EN 50288-7 XLPE Insulation OS Armoured 5x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 5
EN 50288-7 XLPE Insulation OS Armoured 10x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 10
EN 50288-7 XLPE Insulation OS Armoured 20x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 20
EN 50288-7 XLPE Insulation OS Armoured 30x2x1
Nexans ref.
- Conductor cross-section: 1 mm²
- Number of pairs: 30
EN 50288-7 XLPE Insulation OS Armoured 1x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 1
EN 50288-7 XLPE Insulation OS Armoured 5x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 5
EN 50288-7 XLPE Insulation OS Armoured 10x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 10
EN 50288-7 XLPE Insulation OS Armoured 20x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 20
EN 50288-7 XLPE Insulation OS Armoured 30x2x1,34
Nexans ref.
- Conductor cross-section: 1.34 mm²
- Number of pairs: 30
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These compensation and extension cables are used with thermocouples for temperature measurements. They are well adapted to underground use in industrial applications where hydrocarbons may be present and where chemical and mechanical protections are needed (refinery areas, chemical plant…).
Design
Conductor:
Metals in accordance with the thermocouple, either solid cross section 0.5 mm² (1 x 0.8 mm), 1.34 mm² (1 x 1.3 mm) or flexible of cross section 1 mm² (14 x 0.30 mm)
Insulation:
Cross-linked polyethylene (XLPE)
Overall screen:
Binder tape
Tinned copper drain wire
Aluminium backed polyester tape
Bedding:
Polyvinyl chloride (PVC)
Colour : black or depends on thermocouple type
Armour:
Galvanized steel wires (SWA)
Outer sheath:
Polyvinyl chloride (PVC)
Colour: depends on thermocouple type
Core identification
See "identification sheet"
Marking
NEXANS 279 XLPE/OA.SCR/PVC/SWA/PVC 170/300 V Nber of pairs & cross section Type of thermocouple IEC 60332-3-22(A) MM YYYY Manufacturing number + meter marking
Standards
EN 50288-7 (Design guide-lines)
HD 446.3 S1
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations