Instrumentation cables XLPE insulation for fossil power plant

Description

Description

Standards

  • Test
    IEC 60332-3-22 Cat.A

Applications

These Instrumentation and communication are used to transmit analogue or digital signals in measurement and process control for fossil power plant. When they are armoured, they are well adapted to underground use in industrial applications where mechanical protection is needed. The individual screening of each pair limits the consequence of crosstalk.

 

Design

Conductor:

PAS 5308: Solid (class 1), stranded (class 2) or flexible (class 5) bare copper

EN 50288-7: stranded (class 2) bare copper

Insulation:

Cross-linked polyethylene (XLPE)

Screen:

Collective: polyester tape, tinned copper drain wire, aluminium/polyester tape

or

Individual and collective:  polyester tape, tinned copper drain wire, aluminium/polyester tape + polyester tape, tinned copper drain wire, aluminium/polyester tape

Inner sheath:

None or

Polyvinyl chloride (PVC)

Armour:

None or

Galvanized steel wires (SWA)

Outer sheath:

Polyvinyl chloride (PVC)

Colour: black

Other colour on request.

 

Other conductor material, insulation material, type of armouring, sheath material, fire performances (iEC 60332-1, IEC 60332-3-24(C), IEC 60331) on request.

Core identification

PAS 5308 Pair: black - white
Quad: black - white - red - blue
On request: according to PAS 5308 part 1
EN 50288-7 Pair: white - black
Quad: white - black - red - blue
White core printed with pair number

  

Standards

PAS 5308 and EN 50288-7 (Design guide-lines)
 

Characteristics

Characteristics

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Oil resistance
Yes
Electro magnetic interference resistance
Yes
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
- °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close