74C068 SH C 500V 27x1.5 Cu2 K3 EG Ar

Description

Description

Standards

  • Product
    IEC 60228
  • Test
    IEC 60332-3-23; IEC 60754-1; IEC 60754-2; IEC 61034-2; NF C32-070/C1; NF C32-070/C1

Applications

These control cables alllow connection to a variety of industrial equipement from control room. Many of them require anti-inductive screen (EMI). They are well adapted to underground use.

Construction

Conductor:
- Stranded plain copper (class 2)
Insulation:
- Zero halogen (SH), cross-linked
Assembling:
- Polyester tape (optional)
Overall screen:
- Copper wire braid (CWB) R ≥ 80%
Inner sheath:
- Low smoke, zero halogen (LSZH)
Armour:
- Galvanized steel braid (Tz) ≤ 4 conductors
- Steel tapes (Ar) > 4 conductors
Outer sheath:
- Low smoke, zero halogen (LSZH)
- Colour: grey

Core identification

Black cores printed with white numbers
Optional: with Y/G core

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Plain copper
Type of conductor
Stranded, class 2
Insulation
Halogen-free
Screen
Bare copper braid
Inner sheath
LSZH
Armour type
Steel tapes
Outer sheath
LSZH
Halogen free
IEC 60754-1; IEC 60754-2
With Green/Yellow core
No

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
1.5 mm²
Number of cores
27
Conductor diameter
1.5 mm
Diameter over insulation
2.7 mm
Diameter over screen
18.7 mm
Diameter over inner sheath
21.5 mm
Diameter over armour
22.4 mm
Minimum outer diameter
25.3 mm
Maximum outer diameter
28.4 mm
Approximate weight
1324 kg/km

Electrical characteristics

Electrical characteristics

Max. DC resistance of the conductor at 20°C
12.1 Ohm/km
Maximum DC resistance of the conductor at 90°C
15.400 Ohm/km
Reactance at 50 Hz
0.096 Ohm/km
Short Circuit Current 0,3 s Max
0.39 kA
Short Circuit Current 1 s Max
0.21 kA
Impedance at 50 Hz
12.1 Ohm
Voltage Drop
24.8 V/A.km
Calorific Power
7.2 MJ/m

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 60 °C
Smoke density
-
Fire retardant
NF C 32070 C1; IEC 60332-3-24 (cat.B)
Electro magnetic interference resistance
Yes
U.V resistance
Yes
Life cycle 60years
Yes
Max. conductor temperature in service
90 °C
Nuclear Classification
Class 1 E Non LOCA/K3

Resources

Resources

Documentation

xlsx — 0 B

Selling & delivery Information

Minimum bending radius:

10 x outer diameter
To be doubled during laying operations

Marking

NEXANS 279  Nber of cores & cross-section Cu EG ARME CST 74 C 068 K3 SH 0.3/0.5 (0.6) kV YYYY  Manufacturing number  + metric marking

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close