74C068 SH M 6P1 KCB K3 EG NA

Description

Description

Standards

  • International
    IEC 60332-3-23; IEC 60584-3; IEC 60754-1; IEC 61034-2
  • National
    NF C32-070/C1; NF C32-070/C1; NF C42-324; NF C42-324

Applications

These compensation cables allow connection to control board/process for temperature measurement and thermocouple transmission signal. 

 

Design

Conductor:

Metal in accordance with the thermocouple

Insulation:

Cross-linked halogen free (SH)

Assembling tape (optional):

Overall screen:

Copper wire braid (CWB)

Outer sheath:

Low smoke, zero halogen (LSZH)

Colour: depends on thermocouple type

 

Core identification

According to IEC 60584-3/NFC 42324 

 

Marking

NEXANS 279  Nber of pairs and cross-section Type of thermocouple EG CST 74 C 068 00 K3 SH 0.3/0.5 (0.6) kV YYYY  Manufacturing number  + metric marking

 

Standard

IEC 60332-3-23(B)

 

Quality insurance according ot RCC-E
 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Insulation
Halogen-free
Screen
Copper Braid
Outer sheath
Halogen free
Halogen free
IEC 60754-1

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
1 mm²
Conductor diameter
1.3 mm
Diameter over insulation
2.5 mm
Diameter over screen
15.0 mm
Minimum outer diameter
18.0 mm
Maximum outer diameter
20.4 mm
Approximate weight
431 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
300/500 V

Usage characteristics

Usage characteristics

Fire retardant
NF C 32070 C1; IEC 60332-3-24 (cat.B)
Smoke density
EN/IEC 61034-2
Electro magnetic interference resistance
Yes
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
90 °C
Nuclear Classification
Class 1 E Non LOCA/K3

Resources

Resources

Documentation

Selling & delivery Information

Minimum bending radius:

10 x outer diameter
To be doubled during laying operations

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close