FLAMEX® LLC 240

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50264-1

FLAMEX® LLC (Low Loss Coaxial) are intended for antenna wireless communication systems. This product range offers superior RF shielding effectiveness. It is compatible with all standard coaxial connectors.

 

DESIGN

1. Conductor
Bare Copper

2. Insulation
Foam polyethylene

3. Screen
Aluminium/polyester tape
Tinned copper braid
Separator tape

4. Outer sheath
Cross-linked material EM 104 acc. EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black

Example of marking: DTREN 150063 ANTENNA COAXIAL 50 OHMS - LOW LOSS 240 -  FLAMEX 239 - EDE 2PM719 - week / year - Batch number

 

FIRE SAFETY

FLAMEX® LOW LOSS COAXIAL cables are conform to EN 45545-2 HL3

 

ADDITIONAL INFORMATION

  • Compatible with all standard coaxial connectors
  • Bending radius:
    • Static use: ... x outer cable diameter
    • For installation and occasional movements: ... x outer cable diameter

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Insulation
Foam polyethylene
Taping
Aluminium / Polyester tape
Screen
Tinned copper braid
Separator
Separator Tape
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Nominal outer diameter
6.1 mm
Approximate weight
60 kg/km

Electrical characteristics

Electrical characteristics

Characteristic impedance
50 Ohm
Nominal capacitance
78.0 pF/m
Resistance of inner conductor (DC)
- Ohm/km

Transmission characteristics

Transmission characteristics

Nominal Velocity of Propagation (NVP)
80 %
Minimum return loss 10 to 450 MHz
28 dB
Minimum return loss 450 to 1'000 MHz
26 dB
Attenuation, nom. 450 MHz
17.2 dB/100m
Attenuation, nom. 1800 MHz
35.9 dB/m

Usage characteristics

Usage characteristics

Flame retardant
IEC/EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Electro magnetic interference resistance
Yes
Chemical resistance
Good
Minimum static operating bending radius
60 mm

Resources

Resources

Documentation

xlsx — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close