FLAMEX® FIRE RESISTANT WTB-MVB & CAN BUS 120 Ω

Products

FLAMEX MVB 1x2x0.5²

Nexans ref. 2PM599

  • Packaging: Drum (1000m)
  • Construction type: 1x2x0,5
  • Minimum cable diameter: 9.5 mm
  • Maximum cable diameter: 10 mm
  • Approximate weight: 122 kg/km

 

FLAMEX MVB 4x0.5²

Nexans ref. 2PM600

  • Packaging: Drum (1000m)
  • Construction type: 4x0,5
  • Minimum cable diameter: 10.8 mm
  • Maximum cable diameter: 11.2 mm
  • Approximate weight: 135 kg/km

 

FLAMEX WTB 1x2x0.75²

Nexans ref. 2PM601

  • Packaging: Drum (1000m)
  • Construction type: 1x2x0,75
  • Minimum cable diameter: 11.3 mm
  • Maximum cable diameter: 11.7 mm
  • Approximate weight: 160 kg/km

 

Description

Description

Standards

  • Product
    EN 50464-1; EN 45545-2 (HL3)
  • Test
    EN 50200

DESIGN

1. Conductor

Stranded tinned copper (metric or AWG sizes)

2. Insulation
Special halogen-free INFITTM fire proof material
Quad or Pairs assemblies

3. Screen
Tinned copper braid
Separator tape

4. Outer sheath
Cross-linked material EM 104 or EM 101 acc. EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: red

Example of marking: FLAMEX 239 - ...

ADDITIONAL INFORMATION

  • Fire resistant acc. to:
    • EN 50200 PH 30-60 tested under 110 V
    • EN 50200 PH 90 Ethernet frame loss and transmission parameter
  • Bending radius:
    • Static use: 8 x outer cable diameter
    • For installation and occasional movements: 10 x outer cable diameter

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible stranded
Outer sheath
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Fire resistant
EN 50200 PH90
Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Electro magnetic interference resistance
Yes

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close