FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3 kV 1x25 120°C

Nexans ref. 13105686

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x25 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 25 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x35 150°C

Nexans ref. 10284785

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3kV 1x35 120°C

Nexans ref. 10279846

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 35 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x50 150°C

Nexans ref. 10281173

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3kV 1x50 120°C

Nexans ref. 10284784

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x50 150°C

Nexans ref. 10284786

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x50 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 50 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x70 150°C

Nexans ref. 10261506

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3kV 1x70 120°C

Nexans ref. 13117417

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x70 120°C

Nexans ref. 10282760

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x70 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 70 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3kV 1x95 150°C

Nexans ref. 10267165

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3kV 1x95 120°C

Nexans ref. 10267164

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x95 120°C

Nexans ref. 10282761

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x95 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 95 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3kV 1x120 150°C

Nexans ref. 10270368

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x120 120°C

Nexans ref. 10282762

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x120 150°C

Nexans ref. 10276182

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3 kV 1x120 120°C

Nexans ref. 13117546

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 120 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x150 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3kV 1x150 120°C

Nexans ref. 10285643

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x150 150°C

Nexans ref. 10276181

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x150 150°C

Nexans ref. 10284128

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 150 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3 kV 1x185 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x185 120°C

Nexans ref. 10277617

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x185 150°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX SI EN 50382-2 Type FFXS 1.8/3 kV 1x185 150°C

Nexans ref. 10285211

  • Packaging: Drum (1000m)
  • Conductor material: Plain copper
  • Conductor cross-section: 185 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 150 °C
  • Overload maximum core temperature: 170 °C

 

FLAMEX DTREN150068 EN 50382-2 Type FFXS 1.8/3kV 1x240 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 1.8 / 3 (3.6) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

FLAMEX SI EN 50382-2 Type FFXS 3.6/6kV 1x240 120°C

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor material: Tin plated copper
  • Conductor cross-section: 240 mm²
  • Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
  • Max. conductor temperature in service: 120 °C
  • Overload maximum core temperature: 140 °C

 

Description

Description

Standards

  • Product
    EN 45545-2 (HL3); EN 50382-2; IEC 60228

DESIGN

 

1. Conductor
Extra flexible class 6 copper according to IEC 60228
    - tinned copper for 120°C Class
    - plain copper for 150°C Class

2. Insulation
Cross-linked silicone type EI 111 according to EN 50382-1
Separator: Unweaved tape

3. Screen
Tinned copper wire braid
Separator: Unweaved tape

4. Outer sheath
Cross-linked silicone type EM 107 according to EN 50382-1
Colour: black outer layer

Examples of marking: 
FLAMEX SI - EN 50382-2  - Voltage rate (1800V or 3600V) - cross-section mm² - FFXS - temperature class (120°C or 150°C) - Manufacturing n° -  LYNXEO 279 - week/year
DTREN 150068 - EN 50382-2 - 1800V - cross-section mm² - FFXS - temperature class (120°C) - Manufacturing n° - LYNXEO 279 -  week/year

GUIDE TO USE

 

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 10 x outer cable diameter
    • For installation and occasional movements: 12 x outer cable diameter
  • Pulling tensible force (dynamic) during installation: 50 N/mm² of copper size
  • Mechanical static tensible force: 15N/mm² of copper size

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Extra-flexible class 6
Insulation
High temperature silicone
Screen
Tinned copper braid
Outer sheath
High temperature silicone
Halogen free
EN 60754-1 & EN 60684-2

Usage characteristics

Usage characteristics

Flame retardant
EN 60332-1-2
Fire retardant
EN IEC 60332-3-24 (cat C); EN IEC 60332-3-25 (EN50305)
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-50 ... 120 °C
Electro magnetic interference resistance
Yes
Chemical resistance
Good

Resources

Resources

Related products

FLAMEX® EN 50382 - High temperature flexible power cables
FLAMEX® EN 50382 - High temperature flexible power cables
FLAMEX® EN 50382 - High temperature flexible power cables

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close