TCX® (C) 150/250(300) V
TCX (C) 150/250V 1P0.75
Nexans ref. 10170057
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.0 mm
- Maximum outer diameter: 8.2 mm
- Approximate weight: 72 kg/km
TCX (C) 150/250V 2P0.75
Nexans ref. 10170060
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.8 mm
- Maximum outer diameter: 9.2 mm
- Approximate weight: 101 kg/km
TCX (C) 150/250V 4P0.75
Nexans ref. 10170063
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 13.8 mm
- Approximate weight: 186 kg/km
TCX (C) 150/250V 7P0.75
Nexans ref. 10170096
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 14.0 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 237 kg/km
TCX (C) 150/250V 10P0.75
Nexans ref. 10170100
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 16.5 mm
- Maximum outer diameter: 19.0 mm
- Approximate weight: 398 kg/km
TCX (C) 150/250V 14P0.75
Nexans ref. 10170101
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 18.5 mm
- Maximum outer diameter: 21.0 mm
- Approximate weight: 505 kg/km
TCX (C) 150/250V 19P0.75
Nexans ref. 10170103
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 23.5 mm
- Approximate weight: 641 kg/km
TCX (C) 150/250V 24P0.75
Nexans ref. 10170124
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 24.0 mm
- Maximum outer diameter: 27.0 mm
- Approximate weight: 757 kg/km
TCX (C) 150/250V 1T0.75
Nexans ref. 10170056
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 1
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.2 mm
- Maximum outer diameter: 8.4 mm
- Approximate weight: 78 kg/km
TCX (C) 150/250V 2T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 11.0 mm
- Maximum outer diameter: 13.0 mm
- Approximate weight: 150 kg/km
TCX (C) 150/250V 4T0.75
Nexans ref. 10094219
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.8 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 225 kg/km
TCX (C) 150/250V 1P1.5
Nexans ref. 10170125
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 8.2 mm
- Maximum outer diameter: 9.6 mm
- Approximate weight: 97 kg/km
TCX (C) 150/250V 2P1.5
Nexans ref. 10170126
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 9.4 mm
- Maximum outer diameter: 11.0 mm
- Approximate weight: 157 kg/km
Description
Description
Standards
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
-
InternationalIEC 60298
Application
TCX® (C) 150/250 V armoured twisted pair cables are used for telecommunication and instrumentation purposes. These cables show a low transfer impedance in low frequency and an effective screening in high frequency, making them very suitable for polluted electromagnetic surroundings. TCX® (C) cables are also selected where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor
Stranded bare copper class 2
- Insulation
XLPE (cross-linked polyethylene)
- Assembling
Polyester tape
- Armour
Bare copper braid
- Outer sheath
Polyolefin SHF1 (SHF2 on request)
Colour : grey
Marking
NEXANS 279 TCX (C) Nber of pairs/triads & cross-section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat.A WW YYYY *CE* Manufacturing n°+ metric marking
Core identification
Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania