WINDLINK® MV-RS (N)TSCGEHXOE 66kV (72kV)
(N)TSCGEHXOE 3x120+3x120/3 36/60(72)kV
Nexans ref.
- Insulation sheath thickness: 12.0 mm
- Nominal outer sheath thickness: 3.0 mm
- Minimum cable diameter: 102.5 mm
- Maximum cable diameter: 105.5 mm
- Approximate weight: 14050 kg/km
- Resistance of inner conductor (DC): 0.205 Ohm/km
- Operating capacitances: .16 mF/km
- Permissible current rating in open air: 339 A
(N)TSCGEHXOE 3x150+3x150/3 36/60(72)kV
Nexans ref.
- Insulation sheath thickness: 11.5 mm
- Nominal outer sheath thickness: 3.0 mm
- Minimum cable diameter: 97 mm
- Maximum cable diameter: 104 mm
- Approximate weight: 14300 kg/km
- Resistance of inner conductor (DC): 0.165 Ohm/km
- Operating capacitances: .16 mF/km
- Permissible current rating in open air: 399 A
(N)TSCGEHXOE 3x240+3x240/3 36/60(72)kV
Nexans ref.
- Insulation sheath thickness: 10.0 mm
- Nominal outer sheath thickness: 4.0 mm
- Minimum cable diameter: 107 mm
- Maximum cable diameter: 114 mm
- Approximate weight: 18700 kg/km
- Resistance of inner conductor (DC): 0.102 Ohm/km
- Operating capacitances: .198 mF/km
- Permissible current rating in open air: 538 A
(N)TSCGEHXOE 3x95+3x95/3 36/60(72)kV
Nexans ref.
- Insulation sheath thickness: 12.0 mm
- Nominal outer sheath thickness: 3.0 mm
- Minimum cable diameter: 94 mm
- Maximum cable diameter: 96.5 mm
- Approximate weight: 11860 kg/km
- Resistance of inner conductor (DC): 0.263 Ohm/km
- Operating capacitances: .136 mF/km
- Permissible current rating in open air: 298 A
Description
Description
Standards
-
InternationalIEC 60228
Application
Medium-voltage trailing cable WINDLINK® MV-RS (N)TMCGCHXOE in one-sheath design was developed for special application conditions in wind turbines. The construction is torsion resistant by suspension lengths of 100 m. These cables are specified for medium mechanical stress and for operation under permanent influence of seawater and outdoor use.
Marking
Inkjet-marking (WS), e.g.:
WINDLINK® MV-RS (N)TMCGCXOE 1x185/25 20/35 kV I NEXANS I week/year
Resistance to:
- permanent movement
- permanent vibrations
- compressive stress
- oil
- flame-retardant
- temporary influence of seawater
- weather
- ozone influence
- suitable for torsion up to +/- 80 °/meter, test 2000 cycles
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Construction type
3x95+3x95/3
Conductor material
Bare copper class 5
Material of the inner semi-conductor
-
Insulation
-
Material of the external semi-conductor
-
Insulation colour
-
Inner sheath
-
Outer sheath
-
Halogen free
IEC 60754
Dimensional characteristics
Dimensional characteristics
Conductor diameter (mm)
-
Inner sheath thickness
- mm
Electrical characteristics
Electrical characteristics
Max. Electrical Resistance AC 60Hz 70°C
- Ohm/km
Max. Electrical Resistance AC 60Hz 90°C
- Ohm/km
Inductive reactance
- Ohm/km
Permissible short circuit current
- kA
Operating voltage - range
- kV
Mechanical characteristics
Mechanical characteristics
Maximum tensile strength
- N/mm2
Torsion stress
- °/m
Abrasion resistance
-
Usage characteristics
Usage characteristics
Gases corrosivity
-
Flame retardant
IEC 60332-1-2
Oil resistance
-
Ozone resistance
-
Minimum Bending Radius during installation
- (xD)
Minimum bending radius, static (XD)
-
Smoke density
-
Weather resistance
-