TCX® ( I ) 331 2T1.5

Description

Description

Standards

  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60331-1 or 2; IEC 60331; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
  • International
    IEC 60298

Application

TCX® (I) 331  150/250 V fire resistant armoured individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables provide strong protection aganist cross-talk in both low and high frequency runs, making them suitable for highly polluted electromagnetic surroundings. TCX®(I) 331  cables are used for detection and warning systems where enhanced mechanical protection is required. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

  1. Conductor:
    Stranded bare copper
    Class 2
     
  2. Insulation:
    Mica tape + XLPE (cross-linked polyethylene)
    Optional: Special fire resistant HF 90 (halogen-free compound)
    with INFITTM technology
  3. Individual screen:
    Alu/polyester tape with a tinned copper drain wire
  4. Inner covering:
    Lapped polyester tape
  5.  Armouring:
     Bare copper braid
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: orange

 

Marking

I NEXANS I TCX (I) 331 150/250 V  "n" x 2 or 3 x "s" mm²  90°C IEC 60092-376 IEC 60332-3-22 Cat. A  IEC 60331-1/2 "ww/yy" * CE *  TCIF + metric marking

 

 

 

Core identification

Core 1: white
Core 2: blue
Core 3: red
Double identification: core and pair.

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Halogen free
IEC 60754-1
Sheath colour
Orange
Insulation
HFFR special
Screen
Bare copper braid
Outer sheath
Polyolefin
Conductor flexibility
Stranded class 2
Drain wire
Bare copper
Protection
Polyester tape(s)

Dimensional characteristics

Dimensional characteristics

Number of pairs
-
Number of triples
2
Conductor cross-section
1.5 mm²
Nominal outer diameter
17.5 mm
Minimum outer diameter
16.5 mm
Maximum outer diameter
19.0 mm
Approximate weight
410 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
150 / 250 (300) V
Max. DC resistance of the conductor at 20°C
25.6 Ohm/km

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Fire resistant
IEC 60331-21, IEC 60331-1 or 2
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
Operating temperature, range
-30 ... 80 °C
Standard
IEC

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close