- Markets
- Products
- Services
- Newsroom
- Tools & Resources
- About Nexans
- Search
- Contact us
- Compare
- Sign in
TX® (C) 331 - 150/250 (300) V
TX® (C) 331 - 150/250 (300) V
INSTRUMENTATION, CONTROL and COMMUNICATION CABLES
Read moreTX® (C) 331 150/250V 2P0.75
Nexans ref. 10171345
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 7.8 mm
- Maximum outer diameter: 9.2 mm
- Approximate weight: 110 kg/km
TX® (C) 331 150/250V 4P0.75
Nexans ref. 10171347
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.0 mm
- Approximate weight: 170 kg/km
TX® (C) 331 150/250V 7P0.75 Grey
Nexans ref. 25405353
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 16.5 mm
- Approximate weight: 270 kg/km
TX® (C) 331 150/250V 10P0.75
Nexans ref. 10284326
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 20.0 mm
- Approximate weight: 410 kg/km
TX® (C) 331 150/250V 14P0.75
Nexans ref. 10284327
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 22.5 mm
- Approximate weight: 510 kg/km
TX® (C) 331 150/250V 19P0.75
Nexans ref. 10284328
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 22.5 mm
- Maximum outer diameter: 25.5 mm
- Approximate weight: 670 kg/km
TX® (C) 331 150/250V 24P0.75
Nexans ref. 10284329
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 25.5 mm
- Maximum outer diameter: 28.5 mm
- Approximate weight: 860 kg/km
TX® (C) 331 150/250V 2T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 11.0 mm
- Maximum outer diameter: 14.0 mm
- Approximate weight: 190 kg/km
TX® (C) 331 150/250V 4T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 13.0 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 240 kg/km
TX® (C) 331 150/250V 7T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 19.5 mm
- Approximate weight: 390 kg/km
TX® (C) 331 150/250V 10T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- Conductor cross-section: 0.75 mm²
- Minimum outer diameter: 20.0 mm
- Maximum outer diameter: 23.0 mm
- Approximate weight: 570 kg/km
TX® (C) 331 150/250V 2P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 9.0 mm
- Maximum outer diameter: 10.5 mm
- Approximate weight: 160 kg/km
TX® (C) 331 150/250V 4P1.5 Blue
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 13.5 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 260 kg/km
TX® (C) 331 150/250V 7P1.5
Nexans ref. 10171358
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 19.0 mm
- Approximate weight: 420 kg/km
TX® (C) 331 150/250V 10P1.5 Grey
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 20.0 mm
- Maximum outer diameter: 23.0 mm
- Approximate weight: 610 kg/km
TX® (C) 331 150/250V 14P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 23.0 mm
- Maximum outer diameter: 25.5 mm
- Approximate weight: 780 kg/km
TX® (C) 331 150/250V 19P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 26.5 mm
- Maximum outer diameter: 29.5 mm
- Approximate weight: 1030 kg/km
TX® (C) 331 150/250V 2T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 13.5 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 270 kg/km
TX® (C) 331 150/250V 4T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- Conductor cross-section: 1.5 mm²
- Minimum outer diameter: 15.0 mm
- Maximum outer diameter: 17.5 mm
- Approximate weight: 370 kg/km
Description
Description
Standards
-
Product448-010-3-10; IEC 60228
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60331-1 or 2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TX® (C) 331 150/250 V fire resistant overall screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables provide a medium protection aganist external electromagnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
- Conductor:
Bare copper
Stranded class 2
- Insulation:
Mica tape + XLPE (cross-linked polyethylene)
Optional: Special fire resistant HF 90 (halogen-free compound)
with INFITTM technology - Collective screen:
Alu/polyester tape with a tinned copper drain wire
- Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: orange
Marking
I NEXANS I - TX (C) 331 150/250 V "n" x 2 or 3" x s" mm² 90 °C IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 ww/yy - *CE* + metric marking
Core identification
Core 1: white
Core 2: blue
Core 3: red
Double identification: core and pair.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania